Technical Data Sheet | General Grade | Glass Fiber Enhanced | Flame Retardant | Flame Retardant With Glass Fiber | Light Diffusion | ||||||||||||||
Items | Method | Unite | 100 | 100-15 | 100-20 | 100-50 | 100G10 | 100G20 | 100G30 | 100G40 | 100-10V30 | 100-10V15 | 100-20V30 | 100-20V15 | 100G05-V15 | 100G10-V15 | 100G20-V15 | 100G30-V15 | 100-1218 |
Physical Property | |||||||||||||||||||
Specific Gravity | ASTM D792 | − | 1.2 | 1.2 | 1.2 | 1.2 | 1.25 | 1.32 | 1.42 | 1.5 | 1.2 | 1.2 | 1.2 | 1.2 | 1.22 | 1.24 | 1.34 | 1.42 | 1.2 |
Water Absorption | ASTM D570 | % | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.19 | 0.18 | 0.17 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.19 | 0.2 | 0.2 |
Molding Shrinkage | ASTM D955 | % | 0.5-0.7 | 0.5-0.7 | 0.5-0.7 | 0.5-0.7 | 0.3-0.5 | 0.2-.04 | 0.1-0.3 | 0.1-0.2 | 0.5-0.7 | 0.5-0.7 | 0.5-0.7 | 0.5-0.7 | 0.4-0.6 | 0.3-0.5 | 0.2-0.4 | 0.1-0.3 | 0.5-0.7 |
Melt Flow Index(300℃,1.2kg) | ASTM D1238 | g/10min | 10 | 15 | 20 | 50 | 12 | 11 | 10 | 8 | 10 | 10 | 20 | 20 | 15 | 10 | 10 | 8 | 10 |
Mechanical Property | |||||||||||||||||||
Tensile Strength(50mm/min) | ASTM D638 | MPa | 60 | 60 | 63 | 55 | 80 | 110 | 120 | 140 | 60 | 60 | 60 | 63 | 65 | 60 | 100 | 120 | 63 |
Elongation tensile Stretch(50mm/min) | ASTM D638 | % | ≥80 | ≥80 | ≥70 | ≥40 | 8 | 6 | 3 | 3 | ≥70 | ≥70 | ≥70 | ≥70 | ≥10 | ≥80 | ≥5 | ≥3 | ≥80 |
Flexural Strength(10mm/min) | ASTM D790 | MPa | 90 | 90 | 90 | 95 | 100 | 130 | 150 | 180 | 90 | 90 | 90 | 90 | 120 | 95 | 130 | 150 | 90 |
Flexural Modulus(10mm/min) | ASTM D790 | MPa | 2300 | 2300 | 2300 | 2200 | 3300 | 4600 | 6000 | 8000 | 2300 | 2300 | 2300 | 2300 | 2400 | 2300 | 5000 | 6800 | 2300 |
Notched impact strength(23℃) | ASTM D256 | KJ/m2 | 80 | 75 | 75 | 50 | 9 | 9 | 10 | 8 | 75 | 70 | 75 | 70 | 20 | 65 | 10 | 12 | 75 |
Thermal Property | |||||||||||||||||||
Heat Deflection Temperature(1.8MPa) | ASTM D648 | ℃ | 130 | 130 | 128 | 125 | 130 | 134 | 140 | 140 | 140 | 130 | 128 | 128 | 128 | 115 | 136 | 140 | 130 |
Flammability | UL94 | 1.5mm | − | − | − | − | − | − | − | − | − | V0 | − | V0 | V0 | V0 | V0 | V0 | − |
Flammability | UL94 | 3.0mm | HB | HB | HB | HB | V2 | V2 | V2 | V2 | V0 | V0 | V0 | V0 | V0 | V0 | V0 | V0 | V2 |
Electrical Property | |||||||||||||||||||
Dielectric Strength(3mm) | IEC 60243-1 | MV/mm | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | |
CTI(23℃) | IEC60112 | V | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | |
Surface Resistivity | IEC 60093 | Ω | |||||||||||||||||
Volume Resistivity | ICE 60093 | Ω.cm |
Technical Data Sheet | General Grade | Glass Fiber Enhanced | Flame Retardant | Flame Retardant With Glass Fiber | Light Diffusion | ||||||||||||||
Items | Method | Unite | 100 | 100-15 | 100-20 | 100-50 | 100G10 | 100G20 | 100G30 | 100G40 | 100-10V30 | 100-10V15 | 100-20V30 | 100-20V15 | 100G05-V15 | 100G10-V15 | 100G20-V15 | 100G30-V15 | 100-1218 |
Physical Property | |||||||||||||||||||
Specific Gravity | ASTM D792 | − | 1.2 | 1.2 | 1.2 | 1.2 | 1.25 | 1.32 | 1.42 | 1.5 | 1.2 | 1.2 | 1.2 | 1.2 | 1.22 | 1.24 | 1.34 | 1.42 | 1.2 |
Water Absorption | ASTM D570 | % | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.19 | 0.18 | 0.17 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.19 | 0.2 | 0.2 |
Molding Shrinkage | ASTM D955 | % | 0.5-0.7 | 0.5-0.7 | 0.5-0.7 | 0.5-0.7 | 0.3-0.5 | 0.2-.04 | 0.1-0.3 | 0.1-0.2 | 0.5-0.7 | 0.5-0.7 | 0.5-0.7 | 0.5-0.7 | 0.4-0.6 | 0.3-0.5 | 0.2-0.4 | 0.1-0.3 | 0.5-0.7 |
Melt Flow Index(300℃,1.2kg) | ASTM D1238 | g/10min | 10 | 15 | 20 | 50 | 12 | 11 | 10 | 8 | 10 | 10 | 20 | 20 | 15 | 10 | 10 | 8 | 10 |
Mechanical Property | |||||||||||||||||||
Tensile Strength(50mm/min) | ASTM D638 | MPa | 60 | 60 | 63 | 55 | 80 | 110 | 120 | 140 | 60 | 60 | 60 | 63 | 65 | 60 | 100 | 120 | 63 |
Elongation tensile Stretch(50mm/min) | ASTM D638 | % | ≥80 | ≥80 | ≥70 | ≥40 | 8 | 6 | 3 | 3 | ≥70 | ≥70 | ≥70 | ≥70 | ≥10 | ≥80 | ≥5 | ≥3 | ≥80 |
Flexural Strength(10mm/min) | ASTM D790 | MPa | 90 | 90 | 90 | 95 | 100 | 130 | 150 | 180 | 90 | 90 | 90 | 90 | 120 | 95 | 130 | 150 | 90 |
Flexural Modulus(10mm/min) | ASTM D790 | MPa | 2300 | 2300 | 2300 | 2200 | 3300 | 4600 | 6000 | 8000 | 2300 | 2300 | 2300 | 2300 | 2400 | 2300 | 5000 | 6800 | 2300 |
Notched impact strength(23℃) | ASTM D256 | KJ/m2 | 80 | 75 | 75 | 50 | 9 | 9 | 10 | 8 | 75 | 70 | 75 | 70 | 20 | 65 | 10 | 12 | 75 |
Thermal Property | |||||||||||||||||||
Heat Deflection Temperature(1.8MPa) | ASTM D648 | ℃ | 130 | 130 | 128 | 125 | 130 | 134 | 140 | 140 | 140 | 130 | 128 | 128 | 128 | 115 | 136 | 140 | 130 |
Flammability | UL94 | 1.5mm | − | − | − | − | − | − | − | − | − | V0 | − | V0 | V0 | V0 | V0 | V0 | − |
Flammability | UL94 | 3.0mm | HB | HB | HB | HB | V2 | V2 | V2 | V2 | V0 | V0 | V0 | V0 | V0 | V0 | V0 | V0 | V2 |
Electrical Property | |||||||||||||||||||
Dielectric Strength(3mm) | IEC 60243-1 | MV/mm | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | |
CTI(23℃) | IEC60112 | V | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | |
Surface Resistivity | IEC 60093 | Ω | |||||||||||||||||
Volume Resistivity | ICE 60093 | Ω.cm |